| Chairpersons
& Publications
Draft Standards & Task Group Projects
Meeting Schedule & Minutes
Report on DMX512 Over Cat 5 Cable
Alternate START Codes
Manufacturer IDS
RDM additional messages
|
Report on DMX512 over Cat 5 Cable
In response to a perceived industry requirement for lower cost
DMX512 cable installations, the DMX-over- Category 5 Cable Task
Group was formed by ESTA's Control Protocols Working Group (CPWG)
at the January 1998 TSP meetings. The Task Group's mission was
to employ an independent laboratory to carry out a series of
comparison tests between a typical cable presently used for
hardwired DMX512 installations, and conventional Category 5
data cable. The goal of this testing was to establish whether
Category 5 cable, or "generic premises cable" as it has become
known, could be used as a low cost substitute in permanently
wired DMX512 installations. Two series of lab tests were conducted
in July and November of 1998 at MPB Technologies in Airdrie,
Alberta. Additional tests were conducted in December of 1999.
The summary of this
report (PDF, 15kB) describes the tests and gives the general
conclusions.
Part 1 of this report
(PDF, 1.07MB) gives the details of the first series of tests
that compared the DMX512 handling characteristics of a typical
EIA-422 rated data cable with those of a standard Category 5
unshielded twisted pair (UTP) cable. Radiated emissions tests
were also done. Results of these tests indicated that Category
5 UTP cable performed as well as conventional DMX512 cable.
Part 2 of this report
(PDF, 429kB) details the second series of tests that were carried
out with Category 5 shielded twisted pair (STP) cable, and also
included radiated and induced signal immunity tests to current
IEC standards on all cable types.
Part 3 of this report
(PDF, 390kB) details the third series of tests that were conducted
to determine the effect of combining different types of cable
(i.e., Category 5 and EIA-485) on the same wire run. At this
time, tests were also done with Rosco/ET IPS equipment to determine
whether the use of Category 5 cable caused any timing problems
with the talkback data.
|